The R Series Rotary screw air compressors offer the ultimate in advanced features and productivity. The technology used in these is not just state of the art, it is also thoroughly tested.
| n Ingersoll Rand Nirvana Standard - 50Hz Performance | ||||||||||
| Model | Max.Pressure | Nominal Power | Capacity (FAD)** | Dimensions (Length x Width x Height) | Weight (Air- cooled) | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| bar g | psig | kW | hp | M3/MIN | cfm | mm | in | kg | lb | |
| R55 n | 4.5-10.0 | 65 -145 | 55 | 75 | 3.23 - 10.53 | 114-372 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,420 | 3,131 |
| R75 n | 4.5-10.0 | 65 -145 | 75 | 100 | 3.23 - 13.56 | 114- 479 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,420 | 3,131 |
| n Ingersoll Rand Nirvana Total Air System(TAS) - 50Hz Performance | ||||||||||
| Model | Max.Pressure | Nominal Power | Capacity (FAD)** | Dimensions (Length x Width x Height) | Weight (Air- cooled) | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| bar g | psig | kW | hp | M3/MIN | cfm | mm | in | kg | lb | |
| R55 n TAS | 4.5-9.5 | 65 -135 | 55 | 75 | 3.23 - 10.11 | 114-357 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,570 | 3,462 |
| R75 n TAS | 4.5-9.5 | 65 -135 | 75 | 100 | 3.23 - 12.94 | 114- 457 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,570 | 3,462 |
| i Ingersoll Rand Standard - 50Hz Performance | ||||||||||
| Model | Max.Pressure | Nominal Power | Capacity (FAD)** | Dimensions(Length x Width x Height) | Weight (Air- cooled) | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| bar g | psig | kW | hp | M3/MIN | cfm | mm | in | kg | lb | |
| R55 i | 7.5 | 110 | 55 | 75 | 10.19 | 360 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,603 | 3,533 |
| 8.5 | 125 | 55 | 75 | 9.43 | 333 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,603 | 3,533 | |
| 10.0 | 145 | 55 | 75 | 8.58 | 303 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,603 | 3,533 | |
| 14.0 | 200 | 55 | 75 | 6.51 | 230 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,603 | 3,533 | |
| R75 i | 7.5 | 110 | 75 | 100 | 14.21 | 502 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,718 | 3,787 |
| 8.5 | 125 | 75 | 100 | 12.77 | 451 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,718 | 3,787 | |
| 10.0 | 145 | 75 | 100 | 11.61 | 410 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,718 | 3,787 | |
| 14.0 | 200 | 75 | 100 | 8.83 | 312 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,718 | 3,787 | |
| i Ingersoll Rand Total Air System(TAS) - 50Hz Performance | ||||||||||
| Model | Max.Pressure | Nominal Power | Capacity (FAD)** | Dimnesions (Length x Width x Height) | Weight (Air- cooled) | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| bar g | psig | kW | hp | M3/MIN | cfm | mm | in | kg | lb | |
| R55 i TAS | 7.0 | 103 | 55 | 75 | 10.19 | 360 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,753 | 3,864 |
| 8.0 | 118 | 55 | 75 | 9.43 | 333 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,753 | 3,864 | |
| 9.5 | 138 | 55 | 75 | 8.58 | 303 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,753 | 3,864 | |
| 13.5 | 193 | 55 | 75 | 6.51 | 230 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,603 | 3,533 | |
| R75 i TAS | 7.0 | 103 | 75 | 100 | 13.34 | 471 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,868 | 4,118 |
| 8.0 | 118 | 75 | 100 | 12.77 | 451 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,868 | 4,118 | |
| 9.5 | 138 | 75 | 100 | 11.61 | 410 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,868 | 4,118 | |
| 13.5 | 193 | 75 | 100 | 8.83 | 312 | 2432 x 1265 x 2032 | 96 x 50 x 80 | 1,868 | 3,787 | |
| * FAD (Free Air Delivery) is full package performance including all losses.Tested per ISO 1217:2009 Annex C and is measured at 0.5 bar g/10 psig lower than maximum pressure on non- TAS units and at maximum pressure on TAS - equipped units. | ||||||||||
| ** FAD(Free Air Delivery) is full package performance including all losses. Tested per ISO 1217:2009 Annex C and capacity range is measured at 7 bar g /100 psig. | ||||||||||
| TAS units deliver ISO Class 1-4-2 quality air measured at steady state conditions in accordance with ISO 8573-1:2001 that dictates inlet air to package of 250°C (77°F) and relative humidity of 60 % | ||||||||||